+ | ===== port pinning ===== | ||
+ | < | ||
+ | JP-3163B ver. 3.9 | ||
+ | Pin 1: Spindle on/off Relay 1(active low) | ||
+ | Pin 2: X Axis Step (active low) | ||
+ | Pin 3: X Axis Dir (active low) | ||
+ | Pin 4: Y Axis Step (active low) | ||
+ | Pin 5: Y Axis Dir (active low) | ||
+ | Pin 6: Z Axis Step (active low) | ||
+ | Pin 7: Z Axis Dir (active low) | ||
+ | Pin 8: A Axis Step (active low) | ||
+ | Pin 9: A Axis Dir (active low) | ||
+ | Pin 10:Estop (active low) | ||
+ | Pin 11: X Axis Limit Switch (active high) = when NC switch(es) open | ||
+ | Pin 12: Y Axis Limit Switch (active high) | ||
+ | Pin 13: Z Axis Limit Switch (active high) | ||
+ | Pin 14: Buffer Chips “Enable” controlled by computer if Jumper 3 is set to 1-2 position | ||
+ | Pin 15: Probe (active low) | ||
+ | Pin 16: Is supposed to turn Relay 2 on/off but is currently not connected in board. | ||
+ | Pin 17: PWM 0-10V for VFD Spindle AN1 (if jumper 4 is in default 1-2 position) active low | ||
+ | Pin 18: Gnd | ||
+ | Pin 19: Gnd | ||
+ | Pin 20: Gnd | ||
+ | Pin 21: Gnd | ||
+ | Pin 22: Gnd | ||
+ | Pin 23: Gnd | ||
+ | Pin 24: Gnd | ||
+ | Pin 25: Gnd or NC | ||
+ | </ | ||
+ | |||
+ | ===== sheme ===== | ||
+ | * https:// | ||
+ | * https:// | ||
+ | |||